MPS-3033XP Series

Tri-channel programmable DC power supply

我是段落。点击这儿添加你的文字并编辑它,非常容易。-双击进行编辑
我是段落。点击这儿添加你的文字并编辑它,非常容易。-双击进行编辑

◆ Three channels show and adjust current and voltage at the same time 

◆ Intelligent temperature controlled fun to reduce the noise
◆ Serial/Parallel/Track mode
◆ With SENSE function
◆ 40 groups of storage

Precision Impedance Analyzer

MCR-9000

Signal source frequency range: DC, 10Hz~5/10/20/30MHz

 Basic impedance measuring acuracy: ±0.05%

◆ Source position: variable voltage 10mV~2V/Variable current 200uA~20mA

◆Output impedance 25Ω/100Ω, switchable

◆ CC,CV,CR,CP,short circuit,dunamic and other working modes
◆ OVP,OCP,OPP,OHP,multiple protection functions
◆ Accuracy of 0.1%
◆Automatic test function setting
◆ RS-232 interface

PEL-8000 Series

Electronic load

◆Voltage 1mV, Current 0.1mA resolution

◆9 groups storage function

◆Linear power supply, low ripple and noise

◆Over limit alarming function

◆ RS-232 interface

MPS-3600H Series

High precision DC Power supply

MDM-8145A/MDM-8146A Benchtop Digital Multimeter

  • 4½ digits, 22000 counts.
  • Dual parameter display: display two parameters of the same input signal.
  • Measurement rate: FAST (7 times / sec), MID (5 times / sec), SLOW (2 times / sec).
  • Trigger mode: Automatic trigger, single trigger, external trigger(optional).
  • Range switching mode: Auto / Manual.
  • 12 basic measurement functions: AC and DC voltage, AC and DC current, two-wire / four-wire resistance, period / frequency, diode, on-off test, capacitance, duty cycle.
  • DCV basic accuracy: 0.05%.
  • Mathematical functions: MX+B/MAX/MIN/dB/dBm/Rel/Comp Hi/Comp Low/ Statistics.
  • Additional functions: Data hold, data record, data readback.
  • keys can be locked.
  • Open calibration function.
  • Square wave output.(Optional.)
  • Provide system settings, can configure the language(Chinese / English), buzzer, screen brightness, interface display style.
  • Temperature: Thermocouple: K/N/R/S/T/B/E/J/WRe325/WRe526; RTD: PT100 / PT50 / Cu100 / Cu50.
  • Communication Interface: Standard: USB Device; Optional: RS232, USB Host, GPIB, LAN, WIFI, Bluetooth.
  • Support SCPI protocol.
  • Mode

    MDM8145A

    Display digits

    22000(4½)

    Maximum measurement speed

    7 times / sec

    Function

    DC voltage

    DC current

    AC voltage

    AC current

    Accuracy

    ±(0.05%+3)

    ±(0.35%+10)

    ±(0.8%+80)

    ±(0.8%+80)

    Range

    10uV~1000V

    10nA~10A

    10uV~750V

    10nA~10A

    Highest resolution

    10uV

    10nA

    10uV

    10nA

     

    --

    40Hz~100kHz

    40Hz~10kHz

    Function

    Resistance

    Capacitance

    Frequence

    Period

    Accuracy

    ±(0.1%+6)

    ±(3.5%+30)

    ±(0.2%+10)

    ±(0.2%+10)

    Range

    10mΩ~200MΩ

    1pF~10mF

    1Hz~20MHz

    50ns~500ms

    Highest resolution

    10mΩ

    1pF

    0.001Hz

    0.01ns

    Others

    Mathematical functions

    MX+B/MAX/MIN/dB/dBm/Rel/Comp Hi/Comp Low/Hold/Statistics

    Resistance measurement

    Support 2-wire, 4-wire in two ways.

    Continuity test

    When the resistance is less than 30 ohms, the buzzer sounds.

    Diode test

    Measurable range: 02V

    AC+DC measurement

    Support.

    Trigger mode

    Standard: automatic trigger, single trigger; Optional: external trigger.

    Duty cycle measurement

    5.0%95.0%. (the error is within 10 words.)

    Square wave output

    Frequence: 1Hz100kHz, amplitude: 3V.(Optional.)

    Limit test

    Support.

    Calibration

    Support.

    Temperature

    Thermocouple: K/N/R/S/T/B/E/J/WRe325/WRe526; RTD: PT100/PT50/Cu100/ Cu50.

    Communication Interface

    Standard: USB Device; Optional: USB Host, RS232, GPIB, LAN, WIFI, Bluetooth.

    Additional functions

    Data hold, data record, data readback.

Mode

MDM8146

Display digits

22000(4½)

Maximum measurement speed

7 times / sec

Function

DC voltage

DC current

AC voltage

AC current

Accuracy

±(0.02%+3)

±(0.1%+3)

±(0.2%+20)

±(0.3%+3)

Range

10uV~1100V

10nA~12A

10uV~800V

10nA~12A

Highest resolution

10uV

10nA

10uV

10nA

 

--

40Hz~100kHz

40Hz~10kHz

Function

Resistance

Capacitance

Frequence

Period

Accuracy

±(0.05%+5)

±(2%+5)

±(0.05%+3)

±(0.05%+3)

Range

10mΩ~1GΩ

1pF~10mF

1Hz~20MHz

50ns~500ms

Highest resolution

10mΩ

1pF

0.001Hz

0.01ns

Others

Mathematical functions

MX+B/MAX/MIN/dB/dBm/Rel/Comp Hi/Comp Low/Hold/Statistics

Resistance measurement

Support 2-wire, 4-wire in two ways.

Continuity test

When the resistance is less than 30 ohms, the buzzer sounds.

Diode test

Measurable range: 02V

AC+DC measurement

Support.

Trigger mode

Standard: automatic trigger, single trigger; Optional: external trigger.

Duty cycle measurement

5.0%95.0%. (the error is within 10 words.)

Square wave output

Frequence: 1Hz100kHz, amplitude: 3V.(Optional.)

Limit test

Support.

Calibration

Support.

Graphic display

Trend chart, Histogram, Bar Meter.

Customized sensor

Users can customize the relationship curve, through the USB communication port or U disk to download, support up to 20 kinds.

Temperature

Thermocouple: K/N/R/S/T/B/E/J/WRe325/WRe526; RTD: PT100/PT50/Cu100/ Cu50.

Communication Interface

Standard: USB Device; Optional: USB Host, RS232, GPIB, LAN, WIFI, Bluetooth.

Additional functions

Data hold, data record, data readback.

 

 

PV:0